Heating
Furnace
The Matrix
Trinity Boiler
NTI Trinity Boiler
The highest standard in top-quality boilers
- It’s a Boiler and Domestic Hot Water Heater in one.
- The NTI Trinity Boiler is the ultimate in top-quality, high-efficiency boilers.
- This energy saving system wastes little heat and fuel meaning the homeowner saves money.
- It provides lot’s of hot water at very low cost.
- Not only is the NTI Trinity Boiler built for years of dependability, it is an environmental choice which exceeds North American energy and emissions regulations.
How it works
NTI’s combustion system produces the highest industry modulation rates, which allows the TRINITY to modulate the burner to the exact size required to meet the conditions of the system.
The TRINITY incorporates an electronic state-of-the-art combustion system to reduce the amount of gas that is injected into the burner, to ensure proper combustion throughout the full range of modulation.
This system also compensates for extended venting; therefore, adjustments are not required between short and long vent runs.
The TRINITY is a totally sealed combustion system: all combustion air is drawn from outside, used for combustion and then expelled. This eliminates any need for fresh air intake into the room, thereby decreasing heating costs.
Features
- Available in Natural Gas or Propane.
- State of the art sealed modulation combustion system for low heat loss and fuel consumption.
- Instantaneous and up to 5.5 US gallons of domestic hot water per minute at a constant 110°F.
- Patented stainless steel condensing heat exchanger provides ultimate efficiencies
- Sentry 2100 control thermostat
Domestic Hot Water
- NTI has developed a sophisticated heat exchanger that provides virtually endless hot water, at unheard-of efficiencies.
- The TRINITY utilizes its modulation combustion system to electronically increase or decrease the flame size, depending upon the required flow and water temperature. As the water is instantaneously heated and regulated, a storage tank is not required, and energy is not lost due to typical tank standby losses.
- The TRINITY can deliver up to 5.5 US gallons of water per minute at a constant temperature of 110ºF. The TRINITY system automatically gives priority to the domestic hot water system to ensure that all your family’s hot water needs are met.
Patented Heat Exchanger
- The Trinity uses a stainless burner with a metal fiber coating to produce extremely high modulation rates. This interior view of the combustion chamber illustrates the water tube heat exchanger, which is constructed of 316L stainless steel which is a proven material for condensing appliances.
All-New Sentry 2100 Thermostat
- The control is fully enclosed in impact-resistant enclosure
- Multifunctional LED display system.
- Digital set point for unmatched accuracy.
- Provides all safety and operational functions.
- Operates burner, heating pump, and auxiliary indirect pump or valve.
- Provided with outdoor sensor for automatic boiler temperature reset.
- Pump exerciser routine activates pump for five seconds every 72 hours to prevent seizing Internal diagnostic system continuously monitors for errors.
- Designed to withstand power dips and spikes.
Input Rates
General Specifications
| |
Ti100 |
Ti150 |
Ti200 |
Ti400 |
| Size (DxWxL) |
14" x 15.5" x 22" |
14" x 15.5" x 22" |
17" x 15.5" x 22" |
23.5" x 21" x 36" |
| Weight |
80 lbs. |
80 lbs. |
110 lbs. |
205 lbs. |
| Max. Pressure |
30 PSI |
30 PSI |
30 PSI |
145 PSI |
| Gas Type |
Natural, Propane |
Natural, Propane |
Natural, Propane |
Natural, Propane |
| Max. Vent |
105' equivalent |
105' equivalent |
105' equivalent |
4"-30', 6"-65' eqv. |
| Gas Connection Size |
1/2" NPT |
1/2" NPT |
1/2" NPT |
3/4" NPT |
| Max. Supply Water |
200°F |
200°F |
200°F |
200°F |
| Min. Return Water |
40°F |
40°F |
40°F |
40°F |
| Oxygen Tube Barrier |
Required |
Required |
Required |
Required |
| Cerfitication |
CSA, AGA, CSAus, *ASME |
CSA, AGA, CSAus, *ASME |
CSA, AGA, CSAus, ASME |
CSA, AGA, CSAus, ASME |
* Optional
Heating specifications
| |
Ti100 |
Ti150 |
ti200 |
Ti400 |
| BTU Input x1000 |
15-100 |
25-150 |
25-200 |
75-399 |
| BTU Output x1000 |
14-93.5 |
23-138 |
22.7-187 |
69-365 |
| S.S.Efficiency |
98% |
98% |
97% |
96% |
| AFUE |
92.7% |
92.7% |
92.7% |
92.7% |
| Head Loss @ GPM |
12' @ 8 |
12' @ 8 |
13' @ 10 |
9' @ 20 |
| Supply - Return |
3/4" NPT |
3/4" NPT |
1" on H, 3/4" on C Models |
11/4 " NPT |
| Boiler Modulation Ratio |
6.6:1 |
6:1 |
8:1 |
5.3:1 |
| Flow Switch |
Optional |
Optional |
Optional |
Installed |
Domestic Hot Water
| (Combi Version |
Ti150 |
Ti200 |
| Supply - Return |
3/4" NPT Outlet 1/2" Inlet |
| DWH Pressure Drop |
1 PSI |
| Head Loss @ GPM |
15' @ 8 |
18' @ 10 |
| Temperature Regulation |
Electronic Modulation |
| D.H.W. Outputs at |
4.0 @ 110°F |
5.5 @ 110°F |
| 45° Inlet Water |
3.5 @ 120°F |
4.8 @ 120°F |
| (GPM @ Water °F) |
3.1 @ 130°F |
4.5 @ 130°F |
Warranty
- 1 year parts